Specification
Warmcel® 100 for lofts and floors conforms to the
requirements of British Standard BS5803, 1985 “Thermal
Insulation for Use in Pitched Roof Spaces in Dwellings”,
Part 3 “Specification for cellulose Fibre Thermal
Insulation for Application by Blowing” and the fire
performance requirements of BS 5803,Part 4:1985 “Methods
for Determining Flammability and Resistance to Smouldering”.
Certification
Registered by BSI Quality Assurance as a Firm of Assessed
Capability to manufacture cellulose fibre thermal
insulation in accordance with BS EN ISO 9003 1994;
licence no. FM372. The assessment is on-going with
random unannounced visits by the BSI Quality Assurance
Inspectorate.
Approval
• Satisfies the requirements of the Building Regulations
B1 (fitness of materials).
• Department of the Environment, Transport and Regions
(DETR). Accepted for use under the Home Energy Efficiency
Scheme and for “Minor Works Assistance Grants”.
• New Housing - Accepted by NHBC, Zurich, Foundation
15 and HAPM for use in lofts and timber frame walls.
Product Type
The insulation is composed of cellulose fibres derived
from waste newsprint treated with fire retardant and
biocidal additives.
Installation
Lofts
It is recommended that the insulation is installed
according to the requirements laid down in BS 5803,Part
5:1985 - “Specification for Installation of Man Made
Mineral Fibre and cellulose Fibre Insulation”, with
additional requirements as set out in the Company's
Installation Manual.
Product
Properties
Test methods referred to in this section are described
fully in BS 5803:1985, Parts 3 & 4.
Corrosion
The insulation does not contain water-soluble substances
likely to accelerate the corrosion of metallic surfaces
with which it comes into contact.
Settlement in lofts - at high humidity
When tested under conditions of high humidity the
material settles by 2.2% against an allowable maximum
5%.
Settlement in lofts - under vibration
When tested under conditions of accelerated vibration
the material settled by 5.3% this should be allowed
for when calculating installed thicknesses.
Electrical wiring
Warmcel® has no deleterious effect on PVC covered
electrical wiring.
Vapour
resistivity
9.3 MNs/gm, tested by wet cup method.
Thermal
Insulation
For calculating the thermal performance for compliance
with building regulations or other statutory regulations
the material has a thermal conductivity (K value)
of 0.035 W/mK in horizontal loft spaces when measured
by a guarded hot plate test to BS 874:1973 - “Methods
of Determining Thermal Insulating Properties”.
U-Values
All U-values are calculated to allow for thermal bridging
using the proportional area method.
Assumed
Roof Construction
10mm tiles on battens, sarking felt, loft space, 100x38mm
joists on 600mm centres with Warmcel® over & between,
10mm plasterboard.
Fire Performance
Warmcel® meets the requirements of the following British
Standard BS5803 tests.
Flammability Resistance Test
A specimen of conditioned insulation is inserted in
a tray having a plasterboard base and wooden sides
representing a typical configuration of joists and
ceiling forming the base of a loft. A small wooden
crib is placed on the surface and inflammable liquid
is added and then ignited. Observations are made of
the occurrence and duration of flaming and smouldering
of the insulation, outside the area covered by the
crib, and the extent of spread of the combustion zone.
Smouldering Resistance Test
A specimen of conditioned insulation is inserted in
a tray similar to that described in 6.3.1. containing
a pre-heated metal cylinder. Observations are made
of the duration of any flaming and smouldering of
the insulation and of the extent of spread of the
combustion zone.
Packaging
The packs are marked with the following information:
• This
product conforms to BS5803:1985,Part 3.
• The product brand name e.g. Warmcel®
• Product Description - Blown cellulose Fibre Insulation.
• Material accidentally soaked should be removed and
replaced.
• Pack weight - 8.0kg
The following
relates to horizontal loft spaces only:
• Maximum percentage settlement 5.3%.
• Average density installed 35kg/m3, settled 34kg/m3.
• Thermal conductivity 0.035W/mK at settled density.
• Health and safety. Warmcel® is non-irritant and
no special precautions are required. A disposable
facemask should be worn when working in confined dusty
areas. When considering COSHH assessments involving
the use of Warmcel® the material should be classed
as non-hazardous.
|